  19 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com power line filter specifications subject to change without notice. dimensions (mm). see appendix a for recommended power cord. see pdi full line catalog for detailed specifications on power cords. right angle, pc board mount filter with iec 60320 ac inlet socket. pasp series mechanical dimensions features the pasp series are offered with right angle pcb mount terminals. this filter with iec connector provides effective equipment protection in line-to-ground noise up to 15 amp, 250vac. these compactly designed filters with low leakage current are well suited for applications that require strict emission standards. these filters are also available for medical application and offer extremely low leakage current to comply with various industry standards. a ground choke can be added to enhance the grounding ability of the circuit. bleeder resistor can also be added to prevent excessive voltages from developing across the filter capacitors when there is no load. applications computer & networking equipment, measuring & control equipment, data processing equipment, laboratory instruments, switching power supplies, other electronic equipment. technical data rated voltage: 115/250vac rated current: 1a, 2a, 3a, 6a, 10a, 15a power line frequency: 50/60hz max. leakage current each line to ground: @ 115vac 60hz: 0.25ma @ 250vac 50hz: 0.45ma @ 115vac 60hz: 2 a* @ 250vac 50hz: 5 a* hipot rating (one minute) line to ground: 2250vdc line to line: 1450vdc temperature range: -25c to +85c (unit: mm) * medical application 36.3 39.8 41.3 28.2 24.4 20.2 21.3 6.5 18.6 20.5 40.0 50.1 g 22.5 30.3 2x 3.3 40.0 30.5 21.8 r5 typ. 2x 3.5 +0.2 +0.2 recommeded panel cutout 18.6 21.3 20.5 4x 2 recommeded pcb layout
20 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com pasp options: = 00 = 50 = 60 = 70 = 80 = 90 - - no bleeder resistor & ground choke bleeder resistor (1/4 w, 1m) bleeder resistor (1/2 w, 1m) bleeder resistor (1/4 w, 1m) & ground choke bleeder resistor (1/2 w, 1m) & ground choke ground choke (100 h) component locations: = 1 = 2 ? = 3 ? = 4 ? = 1m = 2m ? standard type without c(x); c(y) only c(x) & c(y) behind l without c(x) & c(y) without c(y); c(x) only without c(y); c(x) behind l pasp series example & ordering code 01 50 1 c schematics medical schematics attenuation code table: cx inductance per current rating (mh) (f) 1a 2a 3a 6a 10a 15a 0.1 6.5 3.8 2.5 0.8 0.2 0.18 0.015 1.9 1.5 1.1 0.6 0.3 0.18 0.1 3.7 2.7 1.8 0.8 0.3 0.18 0.1 10.5 4.2 2.5 1.05 0.3 0.18 0.047 4.6 3.4 2.5 0.9 0.3 0.18 0.033 9.5 4.3 1.8 0.85 0.3 0.18 0.047 10.5 4 1.2 0.53 0.3 0.18 0.033 5 3.7 1.8 0.6 0.2 0.18 without cx 10.5 6.5 2.5 1.05 0.3 0.18 non-medical applications, select attenuation code with corresponding component values from the table. = a = b = c = d = e = f = g = h = i c x g line load l mh l mh cy l n l l n g lg cy r 1 2 g line load l mh l mh cy l n l l n g lg cy r 3 g line load l mh l mh l n l l n g lg r cy cy c x 1m g c x g line load l mh l mh l n l l n lg r 2m g g line load l mh l mh l n l l n lg r c x = m1 = m2 = m3 = m4 = m5 = m6 = m7 = m8 = m8 g g line load l mh l mh l n l l n lg r 4 medical applications, select attenuation code with corresponding component values from the table. cx cy bleeder r inductance per current rating (mh) (f) (pf) (ohms) 1a 2a 3a 6a 10a 15a 0.1 2200 1m 6.5 3.8 2.5 0.8 0.2 0.18 0.015 3300 1m 1.9 1.5 1.1 0.6 0.3 0.18 0.1 3300 1m 3.7 2.7 1.8 0.8 0.3 0.18 0.1 1000 1m 10.5 4.2 2.5 1.05 0.3 0.18 0.047 3300 1m 4.6 3.4 2.5 0.9 0.3 0.18 0.033 3300 1m 9.5 4.3 1.8 0.85 0.3 0.18 0.047 2200 1m 10.5 4 1.2 0.53 0.3 0.18 0.033 2200 1m 5 3.7 1.8 0.6 0.2 0.18 without cx without cy 1m 10.5 6.5 2.5 1.05 0.3 0.18 current rating (a): = 01 = 02 = 03 = 06 = 10 = 15* ? contact pdi for attenuation numbers *15a for ul, csa; 10a for ce, vde
21 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com medical applications non-medical applications pasp series attenuation tables comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 34 38 39 32 16 21 9 26 37 62 51 11 29 32 34 30 19 16 8 23 34 60 48 13 28 35 37 28 22 19 8 19 28 52 44 12 18 22 24 27 25 18 8 18 26 52 45 27 8 13 15 17 16 14 8 18 25 32 28 24 7 12 15 16 14 11 7 17 24 41 32 23 25 31 33 30 24 21 1 5 14 41 46 17 23 27 28 29 24 23 1 5 14 45 58 15 19 22 24 27 27 20 1 4 10 39 50 34 15 21 24 23 21 17 1 4 9 30 49 28 11 16 18 17 16 12 1 4 8 26 45 24 7 13 15 16 14 11 1 3 7 26 39 23 29 33 34 30 20 16 8 24 35 58 45 15 28 35 37 28 22 24 8 20 29 61 48 15 25 33 58 51 56 41 8 20 30 57 47 13 19 26 29 28 25 14 8 18 26 46 43 22 11 16 18 18 16 12 8 18 24 47 36 24 36 41 43 37 32 28 8 23 34 60 53 30 31 37 39 35 29 22 8 22 32 66 55 22 28 35 37 28 21 21 8 20 29 54 44 14 22 28 31 30 27 16 8 18 26 43 43 26 12 16 18 20 19 15 8 18 24 49 42 27 32 37 40 35 29 23 3 15 25 74 58 21 29 33 34 30 16 21 3 16 27 57 50 20 28 35 37 28 22 23 3 13 22 59 48 16 18 23 25 27 26 20 3 12 19 48 49 30 11 16 18 18 17 14 3 11 17 42 38 27 7 13 15 16 14 11 3 11 17 43 30 22 36 41 43 37 31 25 1 12 23 54 57 28 32 37 40 36 30 22 1 11 22 63 59 24 23 27 28 31 30 30 1 10 19 61 52 32 19 26 29 29 25 17 1 8 15 39 45 25 11 16 18 18 17 14 2 8 14 42 34 25 41315161411 1 814482921 36 41 43 37 32 28 3 16 27 64 60 31 31 37 40 36 29 25 3 15 25 80 60 25 20 24 25 26 24 23 3 12 21 47 42 22 14 17 19 22 22 19 3 11 18 43 35 29 11 16 18 18 16 12 3 11 17 48 34 23 32 36 37 28 19 11 1 14 26 53 42 16 29 33 34 31 20 17 1 13 24 61 50 14 23 26 28 31 30 31 1 9 19 54 53 29 16 19 21 24 24 21 2 8 15 56 38 33 11 16 18 18 17 14 2 8 14 41 34 25 comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 34 38 40 32 26 11 8 25 37 71 62 12 29 32 55 48 49 51 8 23 34 68 64 14 28 36 39 45 48 39 8 19 27 58 65 15 18 24 28 44 50 47 8 18 26 43 51 31 8 14 18 33 41 39 8 18 25 29 38 31 7 14 19 34 40 38 7 17 23 39 47 27 25 31 33 30 25 14 1 4 12 50 64 16 24 28 20 53 54 55 1 4 13 53 57 16 19 22 24 27 27 22 1 3 8 48 59 31 15 24 30 44 52 40 1 4 8 36 52 28 11 18 23 39 49 37 1 4 8 26 46 24 7 15 20 38 46 37 1 4 8 25 48 28 29 33 47 53 57 41 8 23 35 73 58 14 28 37 44 52 56 41 8 19 27 74 59 17 25 33 46 53 57 44 8 19 29 63 62 13 19 29 36 49 55 46 8 18 23 50 54 24 11 19 24 41 53 36 8 18 24 51 46 25 7 15 21 37 46 36 7 17 23 39 48 27 36 41 41 49 49 46 8 23 33 62 62 32 36 41 41 49 49 46 8 23 33 62 62 32 28 35 37 41 42 42 8 19 28 56 57 17 21 28 31 41 44 41 8 18 25 45 48 29 12 16 19 45 37 41 8 18 24 52 53 30 7 13 16 28 32 37 7 17 24 32 32 30 32 39 55 55 56 52 3 14 25 75 63 24 29 34 46 56 58 49 3 15 27 67 59 21 28 38 44 51 58 39 3 12 20 66 57 18 18 25 31 49 56 47 3 11 17 55 59 32 11 19 24 40 50 40 3 12 17 48 46 29 7 14 20 39 45 37 3 11 17 50 46 29 36 41 62 54 50 36 1 11 22 64 70 29 32 39 56 56 58 58 1 10 21 76 62 23 23 29 35 53 52 40 1 9 17 66 65 33 19 29 35 51 54 49 2 8 13 47 57 28 11 19 25 40 51 39 2 9 14 46 51 29 41521364438 1 8 14504626 36 41 59 54 54 47 3 15 26 68 71 32 31 37 47 51 49 40 3 14 24 69 63 26 20 25 28 44 49 42 3 12 19 61 57 27 14 19 22 39 48 41 3 11 17 48 50 33 11 17 22 36 42 38 3 11 17 39 55 27 4 14 19 34 40 38 3 12 17 38 42 28 32 34 52 44 44 41 1 14 25 60 66 21 29 32 56 49 50 45 1 12 24 67 62 14 23 27 30 49 52 46 1 9 17 59 69 30 16 20 24 42 51 42 1 8 14 58 52 33 11 17 22 36 41 40 2 8 14 37 54 27 41419333939 1 8 14484228 36 42 43 37 31 36 1 2 5 17 23 33 30 37 39 29 22 27 1 1 3 14 21 13 28 35 37 28 22 31 1 1 2 11 18 12 21 29 32 31 27 17 1 1 1 7 12 23 11 16 18 18 17 14 1 1 1 s 3 9 61215161511 1 1 1 1 3 6 attenuation code a b c d e f g h i current rating 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a attenuation code m1 m2 m3 m4 m5 m6 m7 m8 current rating 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a ? ? ? this table applies to schematic 1m only. visit our website or contact pdi for other schematic attenuation numbers. ? this table applies to schematic 1 only. visit our website or contact pdi for other schematic attenuation numbers. insertion loss in db (50 ohm circuit) insertion loss in db (50 ohm circuit)


▲Up To Search▲   

 
Price & Availability of PASP06-70-1MM2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X